We are here to assist you.
Health Advisor
+91-8877772277Available 7 days a week
10:00 AM – 6:00 PM to support you with urgent concerns and guide you toward the right care.
* Prices shown are indicative. Clicking "Buy" will take you to the retailer's website. Doctar may earn a small affiliate commission at no extra cost to you.
This product is a non-absorbable, synthetic monofilament suture designed for surgical wound closure. It is constructed from polypropylene, a material known for its inertness and high tensile strength, which is retained indefinitely. The suture is undyed, appearing clear or translucent, which can be advantageous in certain surgical fields where visibility is critical.
The monofilament construction minimizes tissue drag and reduces the risk of bacterial harboring compared to braided sutures. Each unit contains a single strand of suture material attached to a specialized needle, pre-packaged in foil for sterility. The suture diameter conforms to USP 3-0 standards, indicating a specific gauge suitable for a range of tissue types and surgical procedures.
The accompanying needle is a 19mm, 3/8 circle Prime Multipass PS-2 needle, engineered for precise tissue penetration and manipulation. The Prime Multipass designation suggests a needle designed for multiple passes through tissue, potentially facilitating efficient suturing in complex closures.
The mechanism of action for this suture involves providing mechanical support to approximated tissues during the healing process. Once placed, the suture holds the wound edges together, preventing dehiscence and allowing the body's natural healing mechanisms to repair the tissue. As a non-absorbable material, polypropylene sutures are intended for permanent placement or until they are intentionally removed by a medical professional.
The material's inert nature minimizes inflammatory responses, contributing to a more favorable healing environment. The suture's smooth surface and monofilament structure allow it to pass through tissue with minimal resistance, reducing trauma to the surgical site and potentially improving patient comfort post-operatively. The high tensile strength ensures that the suture can withstand the forces exerted by wound edges without breaking prematurely.
Key features and benefits of this surgical suture include its non-absorbable nature, ensuring long-term wound support. The use of polypropylene offers excellent biocompatibility and minimal tissue reactivity, reducing the likelihood of adverse reactions. The monofilament design contributes to reduced tissue drag and a lower risk of infection.
The Prime Multipass needle is designed for efficient and controlled tissue penetration, aiding in precise surgical technique. The specific 19mm, 3/8 circle geometry of the needle is optimized for access and maneuverability in various anatomical locations. The USP 3-0 diameter provides a balance between strength and tissue approximation capabilities, making it suitable for a broad spectrum of surgical applications.
The indefinite breaking strength retention means the suture maintains its integrity over time, providing reliable closure.
This product is intended for use by qualified medical professionals, including surgeons, physicians, and surgical nurses, in a sterile operating room environment. It is suitable for a variety of surgical specialties where permanent or long-term tissue approximation is required. Typical applications include general surgery, plastic surgery, cardiovascular surgery, and ophthalmic surgery, among others.
The suture can be employed in procedures requiring secure closure of skin, fascia, muscle, and other soft tissues. Its non-absorbable nature makes it particularly useful in situations where prolonged support is necessary, such as in the repair of hernias or in reconstructive procedures. The specific needle design may also lend itself to procedures requiring precise suturing in confined or delicate areas.
Important usage notes include maintaining strict aseptic technique during handling and placement to prevent contamination and infection. The suture should be handled with appropriate surgical instruments to avoid damage to the suture or needle. Surgeons should select the appropriate suture size and needle type based on the specific surgical procedure, tissue type, and patient condition.
As a non-absorbable suture, it may require removal if used for skin closure, depending on the location and surgeon's preference. The product is supplied sterile and should only be used if the packaging is intact. Disposal of used sutures and needles should follow established medical waste protocols to ensure safety and compliance.
Ethicon Johnson
Ethicon Johnson - NW2826 - Vicryl Sutures USP 1, 1/2 Circle Reverse Cutting Heavy Portt - NW2826 - 12 Foils Box
Ethicon Johnson
Ethicon Johnson - NW9254 - PDS II Sutures USP 0, 1/2 Circle Round Body Heavy NW9254 - 12 Foils Box
Ethicon Johnson
Ethicon Johnson - NW882 - Ethibond Excel Sutures USP 4-0, W882 -12 Foils Box
Ethicon Johnson
Ethibond Sutures USP 4-0, 1/4 Circle Spatulated Ethalloy Double Needle -12 Foils
Ethicon Johnson
Ethibond Sutures USP 5-0, 1/4 Circle Spatulated Ethalloy Double Needle -12 Foils
Ethicon Johnson
Ethicon Johnson - NW682 - Ethibond Sutures USP 4-0, 1/4 Circle Spatulated Micro Point - NW682 -12 Foils
Ethicon Johnson
Ethicon Johnson - NW687 - Ethibond Sutures USP 2-0, 1/2 Circle Tapercut Double Needle - NW687 - 12 foils
Ethicon Johnson
Ethicon Johnson - W6987 - Ethibond Sutures USP 2-0, 1/2 Circle Tapercut 2 - W6987 - 12 Foils Box