The Adlisc Infusion Pump-ADIP 5322 is a medical device designed for the controlled delivery of intravenous fluids and medications. It operates by precisely regulating the flow rate of a liquid from an infusion set into a patient's circulatory system. The pump utilizes a peristaltic mechanism to advance the fluid, ensuring accurate and consistent administration.
This device is engineered to offer a range of infusion modes, catering to diverse clinical needs and patient requirements. Its design prioritizes safety and ease of use, incorporating multiple alarm systems and operational features to support healthcare professionals in delivering patient care. The pump's construction includes a removable pump body, facilitating straightforward cleaning and maintenance procedures to uphold hygiene standards within clinical environments.
The unit is powered by a rechargeable lithium-polymer battery, providing operational flexibility when mains power is unavailable, and also supports AC power input for continuous use. Its compact and lightweight form factor enhances portability and usability in various healthcare settings.
The Adlisc Infusion Pump-ADIP 5322 functions by drawing fluid from an infusion bag or bottle through a compatible I.V. set and delivering it at a programmed rate.
It employs an internal mechanism to control the volume and speed of fluid delivery. The device supports multiple infusion modes, including Rate Mode, Drip Mode, Body Weight Mode, and Intermittent Mode, allowing for tailored treatment plans. Key safety features include an anti-reverse rotation detection system, which helps prevent unintended fluid backflow, and a free-flow protection mechanism to mitigate risks associated with accidental unclampage.
An optional drop sensor can be integrated to monitor the drip rate, further enhancing accuracy. The pump is equipped with both visual and audible alarms for a comprehensive range of potential issues, such as air in the line, occlusion, low battery, and door open, alerting users to deviations from programmed parameters or device malfunctions. A double CPU system is integrated to enhance operational safety and reliability by providing redundant processing capabilities.
Key features and benefits of the Adlisc Infusion Pump-ADIP 5322 include its versatility in infusion modes, accommodating various therapeutic regimens. The infusion accuracy is maintained at ≤±5% after calibration, ensuring precise medication delivery. The device offers a broad infusion rate range, from 0.
1 ml/h up to 1200 ml/hr depending on the I.V. set used, and a volume limit adjustable from 1 to 9999 ml.
It incorporates KVO (Keep Vein Open) functionality, allowing for a minimal flow rate (0.1-0.5 ml/hr) to maintain venous access after the primary infusion is complete.
Bolus administration is supported with adjustable rates. The pump features ultrasound-based bubble detection with four levels of air-in-line alarm sensitivity and occlusion alarms with three sensitivity settings. Its compact dimensions (145mm x 100mm x 120mm) and light weight (1.
4kg) contribute to its practical application in diverse clinical settings. The 3.2-inch TF display provides real-time infusion status information.
This infusion pump is intended for use by qualified medical professionals, including nurses, physicians, and other healthcare providers in hospitals, clinics, and long-term care facilities. Patients receiving intravenous therapy under medical supervision may also benefit from its use. Caregivers may be involved in monitoring the device under the guidance of healthcare professionals.
Typical applications include the administration of antibiotics, chemotherapy, pain management medications, intravenous fluids for hydration, and parenteral nutrition. The device is suitable for a wide spectrum of patient populations requiring controlled fluid and medication delivery. The pump operates within specific environmental conditions, including a temperature range of +5°C to +40°C and relative humidity of 10-95%, and requires atmospheric pressure between 86 KPa and 106 KPa for optimal performance.
Important usage notes for the Adlisc Infusion Pump-ADIP 5322 include the requirement to use compatible standard I.V. sets with specified drip factors (15, 20, 60 d/ml) and diameters (3.
4-4.5mm). Proper calibration of the pump with the selected I.
V. set is essential for achieving the stated infusion accuracy. Healthcare professionals should ensure that the chosen infusion mode and parameters (rate, volume limit, bolus settings) are appropriate for the specific medication and patient.
Regular checks of the infusion set for kinks, air bubbles, and occlusions are recommended. The device's battery provides approximately 6 hours of operation at a rate of 25 ml/hr after a full recharge, and users should monitor battery status and connect to AC power as needed. All audible and visual alarms should be promptly addressed by trained personnel to ensure patient safety and the integrity of the infusion therapy.
The pump body should be cleaned according to manufacturer guidelines to prevent contamination. The device is designed for use with standard I.V.
sets and should not be used with incompatible tubing materials or configurations.